FORGOT YOUR DETAILS?

P6015A

75 MHz, 1000X, 20 kV, Single-ended, TekVPI®

Description

For heavy-duty high-performance measurements of voltages over 2.5 kV, Tektronix P6015A is the industry standard. You can measure DC voltages up to 20 kVRMSand pulses up to 40 kV (peak, 100 ms duration). The 75 MHz bandwidth enables you to capture fast, high-voltage signals.

The P6015A uses an environmentally safe silicone compound for a dielectric and never needs refilling. Other features include: A 7-49 pF compensation range, small compensation box that fits on adjacent amplifier inputs, and a readout option for use with most Tektronix digital scopes. With the readout option, displayed voltage amplitude values will be the actual signal value rather than understated by a factor of 1,000.

Key performance specifications
  • DC to 75 MHz
  • High Voltage – 20 kV DC / 40 kV Peak (100 ms Pulse Width)
  • Optional 1000X readout coding
Applications
  • Power supply design
  • Design motor drive
  • Electronic ballast
  • Power semiconductors
  • Switch mode control
  • UPS systems
  • Power converters

Note: Using the readout version with other than Tektronix digital oscilloscopes may result in an erroneous readout display.

0

Specifications

All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.

Nominal length 3 m
Attenuation 100X
Bandwidth 75 MHz
Rise time (typ) 4.0 ns
Loading 100 MΩ/ 3.0 pF
Maximum input voltage, DC or RMS 20 kV
Maximum float voltage N/A
Compensation range (pf) 7 to 49
Readout No
EMC environment and safety UL3111-1, EN61010-1, IEC61010-2-031, CSA1010.1, CSA1010.2.031